  shda100 series 100w desktop power supply for medical equipment ? wide input voltage 90 to 260 vac, 47 to 63hz, ? active power factor correction ? iec - 320 - c14 input inlet ? output voltage available from 11vdc thru 48vdc ? single output ? class i insulation ? input surge current, over voltage, over load and output voltage protection. ? energy star 2.0, cec v, and rohs compliance 2 year warranty approvals: single output product number output voltage max. output current total regulation maximum output power shda100 - s05 11 ~ 13 vdc 9.09 ~ 7.69 a 5% 100w shda100 - s06 13 ~ 16 vdc 7.69 ~ 6.25 a 4% 100w shda100 - s07 16 ~ 21 vdc 6.25 ~ 4.76 a 4% 100w shda100 - s08 21 ~ 27 vdc 4.76 ~ 3.70 a 4% 100w shda100 - s09 27 ~ 33 vdc 3.70 ~ 3.03 a 3% 100w shda100 - s11 40 ~ 48 vdc 2.50 ~ 2.08 a 3% 100w the total regulation each model is required to use awg#18/3c+awg16/3c/4ft output cable the regulation will be changed by modified output cable. electrical characteristics parameter test conditions min. typ. max. unit input voltage operating voltage 90 260 vac input frequency 47 63 hz power factor correction io=full load, vin=230 vac 0.95 1 output power range vin= 90 to 264 vac 0 100 w input current (low line) io=full load, vin=115 vac 1.35 a input current (high line) io=full load, vin= 230 vac 0.5 a low line inrush current io=full load, 25c, cool start, vin=115vac 44 50 a high line inrush current io=full load, 25c, cool start, vin=230 vac 85 100 a efficiency io=full load, vin=230vac 87 90 % line regulation io=full load 0.5 1 % load regulation vin=230vac 3 5 % over voltage protection 112 132 % over current protection 110 150 % transient response io=full load to half load, vin=100vac 4 ms hold - up time io=full load, vin=110vac 12 ms start up time io=full load, vin=100vac 0.3 1.5 2 s * ripple & noise (peak to peak) full load, vin=90vac 0.5 1 % safety ground leakage current io= full load, vin=240vac 0.15 0.25 ma no - load power consumption no load, vin=240vac 0.5 w temperature coefficient all output - 0.04 0.04 %/c
conditions parameter test conditions min. typ. max. unit operating temperature 0 40 70 c storage temperature - 40 85 c relative humidity 5 95 % operation temperature at 25 , calculated per mil - hdbk - 217f 0.1 m hrs der ate linearly from 100% load at 4 0c to 50% load at 70c approvals and compliances parameter test conditions min. unit dielectric withstanding voltage for primary to secondary primary to secondary 56 56 vdc dielectric withstanding voltage for primary to ground primary to ground 28 28 vdc isolation resistance test voltage = 5 00vdc 50 do emi requirements for cispr - 11 vin=2 3 0vac b class emi requirements for fcc part - 18 vin=1 2 0vac b class mechanical and pin out note: 1. dimensions are shown in mm & inch 2. weight: approx. 4 9 0 - 670gs (exclude the input cord) 3. optional output connector.


▲Up To Search▲   

 
Price & Availability of SHDA100-S11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X